VIESSMANN Vitosol 200-FM vertical flat-plate collector
VIESSMANN Vitosol 200-FM flat collector
with automatic temperature switch-off ThermProtect.
Frame dark blue
Flat-plate collector (vertical) for heating drinking water, heating and swimming pool water via a heat exchanger and for generating process heat. For pitched roof mounting and for free-standing mounting. Design features and design: High-performance collector, vertical design, consisting of a meander absorber with a highly selective, switching coating. Casing made from a circumferentially bent aluminum frame profile, side and rear thermal insulation made from melamine resin foam. Cover made of highly transparent and hail-resistant solar safety glass. Integrated piping for modular construction of collector arrays with up to 12 collectors.
Type | SV2F | |
Collector gross area | 2.51 | m² |
absorber surface | 2:31 | m² |
aperture area | 2.33 | m² |
Broad | 1,056 | mm |
Height | 2,380 | mm |
depth | 90 | mm |
weight | 39 | kg |
content liquid | 1.83 | l |
Performance values Working range of the collector | ||
Optical efficiency (absorber area) | 82.3 | % |
Heat loss coefficient k1 (absorber area) | 4,421 | W/m²K |
Heat loss coefficient k2 (absorber area) | 0.022 | W/m²K² |
Optical efficiency (gross area) | 75.7 | % |
Heat loss coefficient k1 gross area) | 4,069 | W/m²K |
Heat loss coefficient k2 (gross area) | 0.020 | W/m²K² |
Theoretical performance values over the entire temperature range | ||
Optical efficiency (absorber area) | 82.7 | % |
Heat loss coefficient k1 (absorber area) | 4,791 | W/m²K |
Heat loss coefficient k2 (absorber area) | 0.025 | W/m²K² |
Optical efficiency (gross area) | 76.1 | % |
Heat loss coefficient k1 gross area) | 4,410 | W/m²K |
Heat loss coefficient k2 (gross area) | 0.023 | W/m²K² |
Permitted operating pressure in the collector | 6 | bar |
Max standstill temperature | 145 | °C |
Technical data for determining the energy efficiency class (ErP label) | ||
solar panel | ||
aperture area | 2.33 | m² |
collector efficiency | 59 | % |
Collector efficiency (optical) | 82 | % |
Linear heat transfer coefficient | 4.75 | W/(m²K) |
Square heat transfer coefficient | 0.024 | W/(m²K²) |
angle correction factor | 0.89 |
Collector Aperture Area (A_sol) | 2.33m2 |
Type of collector | flat collector |
Design collector | vertical |
Mounting type collector | roof |
Product Type Sales | SV2F |
absorber surface | 2.31 m2 |
energy sources | Solar |